Item Number
WAREFX-VACTOR
Order Now
Price
$1,399.95 Reg.
Quantity
This product is currently unavailable for purchase.
CCI Exposure Calculator - Save 15% Instantly


Submit a Review...

You'll see it at the Long Beach Printwear Show July, 30th - Aug 1st.
PICK IT UP @ THE SHOW & SAVE!!!
Save $200 off the demo equipment!

Customer will need to pickup this equipment on Saturday, August 3rd at the Long Beach Convention Center between 4-5 pm.

Realize the ease, power, versatility, and ultimate contact of Ryonet X-Vactor Vacuum Exposure Unit & Inspection Table.



With thousands of our standard exposure units in the market, we decided it was time to take the next step and make a quality affordable vacuum exposure unit. One of the most important factors to an optimal exposure is very positive contact between the glass, film, and screen. While this can be done manually with compression using weight and foam, a vacuum efficiently extracts all air between the screen frame, film, and glass to insure an extremely close positive contact. Not only is positive contact easily achieved, but the screen remains light safe under the black neoprene blanket. Add to the vacuum blanket a digital timer, two light safe inspection bulbs, and this unit is as user and time friendly as they come.

With 240 watts of high powered UV light the X-Vactor is one of the most powerful fluorescent style exposure units on the market. This unit will expose most dual cure emulsions in approximately 3 minutes and photopolymer emulsions in under a minute. We highly recommend that you always have an exposure calculator in order to determine the optimal exposure time for your emulsion, stencil thickness, and bulb output.




The X-Vactor control panel has 4 easy to use key functions.
  • Time Adjustment
  • Timer On/Off
  • Vacuum Blanket On/Off
  • Light Safe Inspection Bulbs On/Off

  • These 4 controls allow you to easily operate your exposure unit for accurate multi facet use.

    Light Inspection Bulbs

    Two functions, one unit! Two light safe inspection bulbs located on either end of the exposure glass provide bright 100% UV blocked yellow light throughout the glass. This allows your exposure unit to double as a film and screen inspection table. Touchup or splice films, insure proper image alignment on your screen, and inspect for pinholes without having to strain to see what you are doing or worrying about light contamination. Standard light tables this size run upwards of $400 so by combining light safe bulbs with the X-Vactor you've doubled your function and saved money!

    Features:

  • Extremely flexible and durable neoprene vacuum blanket.
  • Heavy duty gas shocks for easy open and close access.
  • Adjustable vacuum lid clamps.
  • Optically clear extremely strong tempered glass.
  • Sturdy T5 extremely strong aluminum construction.
  • Oil free vacuum pump is quiet and powerful.
  • Includes nylon rope to allow air movement between blanket & frame.
  • UL Certified Electrical Components
  • 3 Year limited warranty (excludes blanket, glass, & bulbs)
  • MADE IN THE USA!
  • Assembly instructions and maintenance DVD included.
  • Specifications:
    .
    Overall Dimensions 48"(L) x 32"(W) x 9"(H)
    Optical Clear Tempered Glass 31x38"
    Max Exposure Area 23x33"
    Max Frame Size OD 25x36" (23x31" Recommended)
    Vacuum Blanket Size 31x38"
    UV Fluorescent Bulbs 8
    Light Safe Inspection Bulbs 2 w/ Amber Sleeves
    UV Wattage 240 Watts
    Timer Digital (to .10 Seconds)
    Voltage 115v
    Amps 6.2 amps
    Weight 95lbs
    Ship Weight 150lbs

    Bulbs: Exposure unit bulbs are like tanning bed bulbs, they will slowly loose UV output as they are used. This can be compensated by slightly increasing your exposure time as the bulbs dim. We highly recommend that you always have an exposure calculator in order to determine the optimal exposure time for your emulsion, stencil thickness, and bulb output. We recommend replacing your bulbs when your exposure time has increased more than 25-30% from the original settings.

    Replacement bulbs are available from Ryonet.

    Replacement vacuum blankets are available from Ryonet.


    Pre-Registration Template Transparency on an X-Vactor Exposure Unit w/ light safe bulbs on.

    Pre-Registration Template Transparency: (a $80 value Included W/ X-Vactor)
  • Easily tapes to the X-Vactor Exposure Unit.
  • Scratch Resistant
  • Water Resistant
  • Solvent printed on 4 Mil durable transparency
  • Includes instructional
  • The pre-registration template includes a FREE comprehensive video that demonstrates how to get the consistent results using easy methods. Starting with artwork and film output, we'll show you how to layout your film for optimal exposure and press alignments results. Moving to the darkroom we'll place the film onto the screen using the Pre-Registration Template. When it's all said and done you'll see how quick and easy setup becomes on the press.

    The Pre-Registration Template and procedures can easily double or triple your performance in the darkroom and press setup. Throw away the tape measure and t-square and realize an easier path in registration

    INSTRUCTIONS FOR USE